OBD II LabBeginner bookSchematicsConnectorsConceptsWorking casesBytesFirmware

Worked Cases

Worked cases: observations you can reproduce

Version 0.3.0 · 9 November 2026

These results were computed by the supplied simulator, using its default generic teaching parameters. They are synthetic results, not Toyota measurements or calibration. The example files are generated by the same core used by the dashboard and command-line runner. Each run has a CSV time series, a JSON file containing parameters, states, events and final diagnostic requests, and a human-readable CAN transcript under examples/runs/.

From the unpacked project directory, regenerate everything with:

python3 tools/generate_examples.py

Time-series samples are 100 ms apart; the plant step is 2 ms. A controller change at an exact tick can first appear in the following saved sample. Event timestamps are the better source for fault-detection times. A “stop below 0.5 km/h” and a zero-speed sample are deliberately separate summary fields.

1. Start a single engine ECU and follow the heat

Actual simulator traces for thermal inertia, sensor failure, split-friction ABS and BMU freshness.

Hypothesis: combustion produces torque immediately after cranking, but coolant has thermal inertia. The dyno stand stays stationary even when engine speed rises.

python3 run.py --scenario engine_warmup --output examples/my_warmup

The engine starts from 0 rpm, passes through CRANKING and RUNNING, and reaches a sampled peak of 2263.3 rpm as the script changes accelerator position. At 120 s the actual coolant has risen from 20.0°C to 30.68°C, with 0.05339 L of modeled fuel used. Vehicle speed remains zero because this profile is a stand.

This is partial warm-up. Do not expect operating temperature after every two-minute run. Compare ECU crank speed, mass airflow and coolant PIDs against the physical state. Extend the duration or change the manual load to explore the heat balance; the extra time continues with the script’s final idle input.

2. Disconnect the coolant-temperature sensor

Hypothesis: a sensor reading can be wrong while the physical quantity remains normal; clearing diagnostic memory does not repair that sensor.

python3 run.py --scenario ect_open --output examples/my_ect_fault

At 3.00 s, the ECT circuit becomes open. Its simulated pull-up input is 5.000 V, with a full-scale 4095 ADC count and zero branch current. The branch resistance is null, marked invalid; no finite resistance is reported. The sensor temperature display is −40°C, with invalid measurement status. After 200 ms the teaching ECU marks P0118 pending, uses an 80°C fallback estimate, and applies a 65% torque multiplier. At 3.50 s, P0118 becomes confirmed and the MIL turns on. The final physical coolant is 23.32°C, while the reported sensor remains -40°C. These are distinct signals.

In the final transcript, 01 05 returns 41 05 00; the temperature conversion is 0 − 40 = −40°C. 03 reports P0118, encoded as bytes 01 18. Use the dashboard’s clear button, continue time, and observe the fault returning. These 200/500 ms rules are an accelerated lesson, not regulatory emissions confirmation logic.

Inspect the same cause in the new task workspace

The six task buttons provide a separate interactive setup: Healthy baseline runs 1 s from a selected 25°C coolant initial condition, then Open circuit, +0.20 s, +0.30 s, Read DTC, and Repair & clear expose each transition. This task begins near 25°C; the scripted ect_open recording above retains its 20°C initial condition and its fault at 3.00 s.

Choose ECT electrical circuit, then probe the physical node voltage, ADC count, reported temperature and control temperature. At exactly 25°C the synthetic 2,500 Ω NTC and 2,200 Ω pull-up give 5 × 2500 / 4700 = 2.659574 V. The 12-bit ADC gives count 2178 and reconstructs 2.659341 V. Opening the path separates true coolant temperature from the invalid sensor report and later 80°C fallback.

Invalid, substituted and stale finite scope values use dashed segments. Null resistance leaves a gap. Recorded samples are 100 ms apart, so inspect the event timeline for the monitor’s exact transition time. The workspace guide and connector reference explain the five screens, measurement boundaries and illustrative harness mapping. Clearing the code while the input remains open still allows it to return after the teaching debounce.

3. Follow power through EV, hybrid and braking states

Hypothesis: the supervisor changes sources and braking allocation while the same physical vehicle continues moving.

python3 run.py --scenario phev_city --output examples/my_phev_cycle

The DC link precharges before the contactor closes; torque is inhibited during precharge. The first launch is electric, the first braking event recovers energy, and the later high-demand launch also uses the engine. The vehicle reaches 102.00 km/h, stops twice, and ends at zero speed after 60 s. SOC changes from 75.0% to 74.461%; gross battery discharge is 0.16177 kWh, and gross charge is 0.06572 kWh. Gross charge and net SOC change are different quantities because driving and auxiliaries consume energy during the same run.

This is an educational sequence with deliberately visible transitions, not an EPA, WLTP, Toyota, or standardized urban drive cycle. The transmission is a generic parallel-hybrid approximation, not a Prius planetary gearset.

4. Begin with low SOC

Hypothesis: the engine can support propulsion and a charging request when the supervisor enters charge-sustain operation.

python3 run.py --scenario low_soc --output examples/my_low_soc

The pack begins at 22.0% SOC and ends at 22.420% after 45 s. The supervisor requests up to 5 kW of generator shaft power; the sampled maximum is 5.00 kW. Mode is CHARGE SUSTAIN during traction. Battery current is negative while net charging, and engine fuel use is 0.09741 L. The narrow run increases SOC by only 0.420 percentage points; it is not a complete battery recharge. Generator output is limited when the battery cannot accept charge.

5. Compare ABS on the same split-friction surface

Hypothesis: per-wheel pressure modulation reduces sustained locking in this specified model. Keep every other input identical for the comparison.

python3 run.py --scenario abs_split_mu --output examples/my_abs
python3 run.py --scenario abs_split_mu --set abs_enabled=false --output examples/my_no_abs

Both runs start at 80 km/h, coast for 1 s, then apply 85% braking. Left-road friction is 0.20 and right-road friction is 0.80. The shared first-second coast covers 22.11 m.

Observation ABS enabled ABS disabled
Total distance from time zero 110.32 m 115.51 m
Distance after brake command at 1 s 88.21 m 93.40 m
First saved speed below 0.5 km/h 9.1 s 9.5 s
ABS active time 7.07 s 0.00 s

Inspect the four slip and pressure traces; with ABS disabled, wheels reach locking slip. These distances apply to this toy tire curve, pressure controller and fixed conditions. They do not establish real-vehicle stopping performance. The associated yaw-brake assistance is reduced-order and omits lateral tire and body-sideslip states.

6. Ask a nearly full battery to accept regeneration

Hypothesis: restricted charge acceptance moves braking work to friction brakes.

python3 run.py --scenario regen_limit --output examples/my_full_pack_braking
python3 run.py --scenario regen_limit --config examples/normal_soc.json --output examples/my_normal_pack_braking

Both vehicles start at 60 km/h and apply the same 30% brake command after 1 s. Only initial SOC changes: 97.5% versus 75.0%.

Energy over the 35 s experiment 97.5% starting SOC 75.0% starting SOC
Gross battery charge 0.00856 kWh 0.02662 kWh
Mechanical regeneration 0.01157 kWh 0.03209 kWh
Friction-brake dissipation 0.04335 kWh 0.02249 kWh
Total distance 120.60 m 120.60 m

Charge power tapers between 90% and 98% SOC. Mechanical regeneration exceeds stored battery energy because the motor/inverter conversion is lossy and auxiliaries still consume power. The stopping distances remain similar because friction braking fills the request when regeneration is limited.

7. Remove the BMU heartbeat

Hypothesis: a supervisor must distinguish stale data from a healthy unchanged measurement.

python3 run.py --scenario bmu_timeout --output examples/my_missing_bmu

Messages stop at 8.00 s. The last message arrived at 7.90 s; the 20 ms supervisor therefore detects message age greater than 300 ms at 8.22 s. It records the local BMU_STATUS_TIMEOUT teaching label, inhibits torque, and opens the traction path. The car continues coasting and ends at 19.76 km/h. A fault does not magically remove kinetic energy. No generic emissions MIL is asserted for this local network fault.

8. Force a low cell-voltage input

Hypothesis: persistent out-of-range battery sensing causes a latched traction shutdown rather than continued torque production.

python3 run.py --scenario cell_low --output examples/my_low_cell

At 8.00 s one measured cell channel is forced to 2.30 V. The BMU threshold is 2.80 V for 200 ms, so shutdown occurs at 8.20 s. Final contactor status is FAULT, and battery current and traction output are zero. The stored label is BMU_CELL_UNDERVOLTAGE; it is explicitly a teaching identifier, not a claimed Toyota trouble code. Ordinary cells are aggregate pack/96 readings with a nominal spread; this does not model 96 independent cell electrochemistry states. Remove the injection and cycle ignition to reattempt readiness.

Read the recordings critically

examples/RESULTS.csv and RESULTS.json provide the comparison values above. Each .trace.txt contains requests made at the end of its run, not requests polled continuously throughout the CSV. Thus a healthy engine-speed response can be zero at the end of a PHEV stop while earlier records show combustion running.

The battery ledger checks chemical energy = terminal energy + resistive heat. This is a check on the modeled battery equations, not proof of complete vehicle energy closure: precharge resistor/capacitor energy, detailed 12 V loads, lateral motion, full engine maps and several other losses are outside this first model.